Avoid frequent short-interval start-stop operation of the refrigerated air dryer. A minimum interval of 10 minutes is required
between each startup to prevent damage to the refrigeration compressor.
Avoid prolonged no-load operation of the refrigerated air dryer as far as possible.Press the green start button, the contactor will pull in, and the green startup indicator will illuminate. After 5 minutes, the green startup indicator turns off,
the compressor starts to operate, and the green running indicator lights up.
Check whether the compressor runs normally without abnormal noise. Verify that the reading on the refrigerant low-pressure gauge drops to approximately 0.5 MPa (for R22 refrigerant).Observe the equipment for 5–10 minutes. The compressed air treated by the refrigerated air dryer can reach the designed pressure dew point.
The normal operating range of refrigerant high and low pressure for R22 is listed below:
R22 Low-side Pressure: 0.3–0.6 MPaName: Nancy